Back to top
Coupling Cover

Coupling Cover

Product Details:

X

Product Description

Coupling Cover

  • Chain Couplings Covers Plastic / Aluminium
  • Chain Coupling covers are available in Aluminum and Plastic.
  • Aluminum covers are available for all the sizes.
  • Plastic covers are available only for sizes up to NT-1218.

CHAIN COUPLING SIZE

ASA NO.

A

B

Wt. Kg.

NT 1618

8018

195

130

2.3

NT 1622

8022

220

132

2.4

NT 2020

10020

258

178

3.4

NT 2418

12018

292

220

5.9

NT 2422

12022

340

220

7.3

NT 3218

16018

385

240

14

NT 3222

16022

472

250

17

NT 4018

20018

496

280

22

NT 4022

20022

578

280

26

NT 6112

3812

69

59

0.2

NT 8312

4012

75

68

0.2

NT 8316

4016

90

70

0.4

NT 1016

5016

110

86

0.6

NT 1018

5018

121

86

0.8

NT 1218

6018

149

90

1.2

NT 1222

6022

173

110

1.6


Selecting Chain Couplings

Driven Equipment

Prime Mover

Service classification

Kinds

Characteristics

Electric motor or steam turbine

Gasoline engine 4 or more cyl.

Diesel or Gas Engine.

A

Centrifugal Fans, blowers of pumps conveyor evenly loaded.

Even load - 8 hours/day service, Non-reversing-low torque starting.

1

1.5

2.0

B

Compressor, conveyor, pulsating load machines, kilns and driers, speeds reducers, Multi cylinder pumps, wood working machines etc.

Uneven load - 8 hours / day service, moderate shock or torsional loads, non-reversing. This is the most common type of service.

1.5

2.0

2.5

C

Presses, crushers, impact loads, oil well pumping equipment.

Heavy shock load - 8 hours / day service, high peak torsional loads. Reversing under load. Full load starting.

2.0

2.5

3.0

The above table will assist in deciding the service factor for the unit for which the chain coupling is to be fitted by considering the hours of service, type of the power unit etc.

For 8 to 16 hrs/day service use next step service factor.

For 16 to 24 hours/day service use service factor two step higher loading.

  • Multiply horsepower of driver unit by the service factor to obtain the design horsepower.
  • Note the maximum rpm. at which the unit will run and its shaft diameter.
  • From H.P. rating table select the coupling size which is rated equal to or slightly greater than    design H.P. required at the rpm. at which the coupling is to operate.
  • Also make sure that the diameter at the shaft is less than the maximum bore permissible on the coupling. If the coupling is not large enough to accommodate the shaft size, use the next coupling which can be bored to suit the shaft requirement.

Lubrication

Couplings operating without cover under fairly clean conditions will give satisfactory service provided they are brushed thoroughly, once a week, with ball bearing grease of medium consistency.

Couplings operating with covers should be kept filled with a good quality ball bearing grease of soft or medium consistency.



TRANS COILS PVT. LTD.
Patel House, EL-14, J-Block, Electronic Zone, Bhosari Industrial Area,Pune - 411026, Maharashtra, India
Send SMS Send Inquiry
Key Personnel
Mr. Prasad Aranke (Commercial Manager)
Mobile :View Number